1. Double-click on Flash Magic icon located at the desktop to launch the
software.
2. The Figure 6 as shown below will be appearing.
The window is divided
up into five sections. Work your way from section 1 to section 5 to
program a device
using the most common functions. Each section is described in detail in
the following
sections.
At the very bottom
left of the window is an area where progress messages will be displayed
and at the very
bottom right is where the progress bar is displayed. In between the
messages and the
progress bar is a count of the number of times the currently selected hex file
has been programmed since it was last modified or selected.
3. There are a few
settings that need to be configured on the Flash Magic window before
downloading
the hex file:
a) COM Port
is the RS232 port located on the back of the computer. Set the
parameter according to
which COM Port the RS232 cable is plugged into.
b) Baud Rate is
used to set the rate of how fast each data bit is transferred. The
typical value for Baud
Rate is 9600. If there is a massage popped up saying that
the Baud Rate is too
high, then reduce the Baud Rate to 2400.
c) Device is the
8051 microcontroller target device. In our case, it should be assign
to 89LV51RD2.
d) Hex File indicates
the location of the hex file to be programmed. C:\Program
Files\Osram\Pictiva\firmware\Reference Design.hex
e) Verify after
programming option is not required but it is a way to verify whether
the programming process
had been done successfully or not. Before clicking on
the start button
for programming, the 8051 flash has to be erased by selecting
either Erase all
Flash or Erase blocks used by Hex File if the address of that
specific block is known.
4. Press Start Button on Step 5
After Successful finish press reset again to run the downloaded program
No comments: